Enter the Documents Area to download .pdf files
|
FEATURES
|
MODEL |
S – 150 - 12 |
S – 150 - 24 |
|
OUTPUT |
DC VOLTAGE |
12 V |
24 V |
RATED CURRENT |
12,5 A |
6,5 A |
|
CURRENT RANGE |
0 ~12,5 A |
0 ~6,5 A |
|
RATED POWER |
150 W |
156 W |
|
RIPPLE & NOISE (max.) Note.2 |
180 m Vp-p |
240 m Vp-p |
|
VOLTAGE ADJ. RANGE |
10,6 ~ 13,2 V |
21 ~ 28 V |
|
VOLTAGE TOLERANCE Note.3 |
± 1,0 % |
± 1,0 % |
|
LINE REGULATION |
± 0,3 % |
± 0,2 % |
|
LOAD REGULATION |
± 0,3 % |
± 0,2 % |
|
SETUP, RISE, HOLD TIME |
100ms, 50ms, 20ms at full load |
||
INPUT |
VOLTAGE RANGE |
88 ~ 132VAC/176 ~ 264VAC selected by switch |
|
FREQUENCY RANGE |
47 ~ 63 Hz |
||
EFFICIENCY (Typ.) |
82 % |
85 % |
|
AC CURRENT |
3,2 A / 115 VAC 1,6 A / 230 VAC |
||
INRUSH CURRENT (max.) |
COLD STAR 35A |
||
LEAKAGE CURRENT |
< 3,5 mA / 240 VAC |
||
PROTECTION |
OVER LOAD |
105 ~ 150% rated output power |
|
Protection type : Shut down o/p voltage, re-power on to recover |
|||
OVER VOLTAGE |
13,8 ~ 16,2 V |
30 ~ 34,8 V |
|
Protection type : Shut down o/p voltage, re-power on to recover |
|||
ENVIRONMENT
|
WORKING TEMP. |
-10 ~ +60 (Refer to output load derating curve) |
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||
STORAGE TEMP., HUMIDITY |
-20 ~ +85° C , 10 ~ 95 % RH |
||
TEMP. COEFFICIENT |
± 0,03 % / °C (0 ~ 50° C) |
||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
||
SAFETY |
SAFETY STANDARDS |
UL1012, UL1950, TUV EN60950 Approved |
|
WITHSTAND VOLTAGE |
I/P – O/P: 3 KVAC I/P-FG: 1,5 KVAC O/P-FG: 0,5 KVAC |
||
ISOLATION RESISTANCE |
I/P – O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
||
EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
||
HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
||
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A |
||
OTHERS |
MTBF |
286,7K hrs min. |
|
DIMENSION |
199*110*50mm (L*W*H) |
||
PACKING |
0,8 Kg |
||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. |
||


![]() |
FEATURES
|
MODEL |
S – 240 - 24 |
|
OUTPUT
|
DC VOLTAGE |
24 V |
RATED CURRENT |
10 A |
|
CURRENT RANGE |
0 ~10 A |
|
RATED POWER |
240 W |
|
RIPPLE & NOISE (max.) Note.2 |
180 m Vp-p |
|
VOLTAGE ADJ. RANGE |
20 ~ 28 V |
|
VOLTAGE TOLERANCE Note.3 |
± 1,0 % |
|
LINE REGULATION |
± 0,5 % |
|
LOAD REGULATION |
± 0,5 % |
|
SETUP, RISE, HOLD TIME |
1s, 20ms, 20ms at full load |
|
INPUT
|
VOLTAGE RANGE |
88 ~ 132VAC / 176 ~ 264VAC auto switch 248~370VDC |
FREQUENCY RANGE |
47 ~ 63 Hz |
|
EFFICIENCY (Typ.) |
84 % |
|
AC CURRENT |
5A/115VAC 2.5A/230VAC |
|
INRUSH CURRENT (max.) |
18A/115VAC 36A/230VAC |
|
LEAKAGE CURRENT |
< 2mA / 240 VAC |
|
PROTECTION |
OVER LOAD |
105 ~ 135% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
||
OVER VOLTAGE |
31,2 ~ 36 V |
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
||
ENVIRONMENT
|
WORKING TEMP. |
-10 ~ +60 (Refer to output load derating curve) |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|
STORAGE TEMP., HUMIDITY |
-20 ~ +85° C , 10 ~ 95 % RH |
|
TEMP. COEFFICIENT |
± 0,03 % / °C (0 ~ 50° C) |
|
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
|
SAFETY |
SAFETY STANDARDS |
UL1950, TUV EN60950 Approved (7.5V Design refer to UL1950) |
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
|
EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
|
HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
|
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A |
|
OTHERS |
MTBF |
179.3K hrs min. |
DIMENSION |
190*93*65mm (L*W*H) |
|
PACKING |
1.2Kg |
|
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. |
|
![]() |
![]() |
![]() |
FEATURES
|
MODEL |
S P – 320 - 24 |
|
OUTPUT
|
DC VOLTAGE |
24 V |
RATED CURRENT |
13 A |
|
CURRENT RANGE |
0 ~13 A |
|
RATED POWER |
312 W |
|
RIPPLE & NOISE (max.) Note.2 |
150 m Vp-p |
|
VOLTAGE ADJ. RANGE |
20 ~ 26,4 V |
|
VOLTAGE TOLERANCE Note.3 |
± 1,0 % |
|
LINE REGULATION |
± 0,2 % |
|
LOAD REGULATION |
± 0,5 % |
|
SETUP, RISE, HOLD TIME |
800 ms, 50 ms, 16 ms / 230 VAC |
|
INPUT
|
VOLTAGE RANGE |
88 ~ 264 VAC 120~ 370VAC |
FREQUENCY RANGE |
47 ~ 63 Hz |
|
POWER FACTOR |
PF>0,95/230 VAC PF>0,98/115VAC at full load |
|
EFFICIENCY (Typ.) |
87 % |
|
AC CURRENT |
5 A / 115 VAC 2,5 A / 230 VAC |
|
INRUSH CURRENT (max.) |
22 A / 115 VAC 40 A / 230 VAC |
|
LEAKAGE CURRENT |
< 1mA / 240 VAC |
|
PROTECTION
|
OVER LOAD |
105 ~ 135 % rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
||
OVER VOLTAGE |
27,6 ~ 32,4 V |
|
Protection type : Shut down o/p voltage, re-power on to recover |
||
OVER TEMPERATURE |
80 5 (70 5 5V only) (TSW1 : Detect on heatsink of power transistor) |
|
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
||
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +65 (Refer to output load derating curve) |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|
STORAGE TEMP., HUMIDITY |
-40 ~ +85 , 10 ~ 95% RH |
|
TEMP. COEFFICIENT |
± 0,03 % / °C (0 ~ 50° C) |
|
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
|
SAFETY |
SAFETY STANDARDS |
UL60950, TUV EN60950 Approved |
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
|
EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
|
HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
|
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A |
|
OTHERS |
MTBF |
207 K hrs min. |
DIMENSION |
215*115*50mm (L*W*H) |
|
PACKING |
1.1Kg |
|
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. |
|
![]() |
![]() |